.. SPDX-License-Identifier: GPL-2.0
==============================================
SSSRAID - 3SNIC SCSI RAID Controller driver
==============================================
This file describes the SSSRAID SCSI driver for 3SNIC
(http://www.3snic.com) RAID controllers. The SSSRAID
driver is the first generation RAID driver for 3SNIC Corp.
For 3SNIC SSSRAID controller support, enable the SSSRAID driver
when configuring the kernel.
SSSRAID specific entries in /sys
=================================
SSSRAID host attributes
------------------------
- /sys/class/scsi_host/host*/csts_pp
- /sys/class/scsi_host/host*/csts_shst
- /sys/class/scsi_host/host*/csts_cfs
- /sys/class/scsi_host/host*/csts_rdy
- /sys/class/scsi_host/host*/fw_version
The host csts_pp attribute is a read only attribute. This attribute
indicates whether the controller is processing commands. If this attribute
is set to 1, then the controller is processing commands normally. If
this attribute is cleared to 0, then the controller has temporarily stopped
processing commands in order to handle an event (e.g., firmware activation).
The host csts_shst attribute is a read only attribute. This attribute
indicates status of shutdown processing.The shutdown status values are defined
as:
====== ==============================
Value Definition
====== ==============================
00b Normal operation
01b Shutdown processing occurring
10b Shutdown processing complete
11b Reserved
====== ==============================
The host csts_cfs attribute is a read only attribute. This attribute is set to
1 when a fatal controller error occurred that could not be communicated in the
appropriate Completion Queue. This bit is cleared to 0 when a fatal controller
error has not occurred.
The host csts_rdy attribute is a read only attribute. This attribute is set to
1 when the controller is ready to process submission queue entries.
The fw_version attribute is read-only and will return the driver version and the
controller firmware version.
SSSRAID scsi device attributes
------------------------------
- /sys/class/scsi_device/X\:X\:X\:X/device/raid_level
- /sys/class/scsi_device/X\:X\:X\:X/device/raid_state
- /sys/class/scsi_device/X\:X\:X\:X/device/raid_resync
The device raid_level attribute is a read only attribute. This attribute indicates
RAID level of scsi device(will dispaly "NA" if scsi device is not virtual disk type).
The device raid_state attribute is read-only and indicates RAID status of scsi
device(will dispaly "NA" if scsi device is not virtual disk type).
The device raid_resync attribute is read-only and indicates RAID rebuild processing
of scsi device(will dispaly "NA" if scsi device is not virtual disk type).
Supported devices
=================
=================== ======= =======================================
PCI ID (pci.ids) OEM Product
=================== ======= =======================================
1F3F:2100 3SNIC 3S510(HBA:8Ports,1G DDR)
1F3F:2100 3SNIC 3S520(HBA:16Ports,1G DDR)
1F3F:2100 3SNIC 3S530(HBA:32Ports,1G DDR)
1F3F:2100 3SNIC 3S540(HBA:40Ports,1G DDR)
1F3F:2200 3SNIC 3S580(RAID:16Ports,2G cache)
1F3F:2200 3SNIC 3S585(RAID:16Ports,4G cache)
1F3F:2200 3SNIC 3S590(RAID:32Ports,4G cache)
1F3F:2200 3SNIC 3S5A0(RAID:40Ports,2G cache)
1F3F:2200 3SNIC 3S5A5(RAID:40Ports,4G cache)
=================== ======= =======================================